Report
Configuration - User Reports
Reports that are specific to a particular
user can be configured using this page.
To access this page, click on the icon available in the Admin tab. Then, select the User Reports option from the Reporter sub-menu in the Settings tile.
Reports generated using the eG
Reporter are categorized into Network, System, Application,
and Site reports. For configuring user reports belonging to the Network
category, choose the Network option. Then, proceed
as follows:
- Select a user from the Choose the user list.
- Then, select a Report type from the
list box. The options to choose from include:
- Measure : Select this
option if a graph plotting every value of the selected measure(s) is to be generated.
- Summary: Select this
option for generating a graph that depicts the hourly, daily or
monthly summary of the variations in the selected measure(s).
- Once a Report type is selected, all the measures that were
previously associated (if any) with the given combination of user, Category type
, and Report type, will be displayed.
- Next, the test that are applicable for the selected component will be listed. To modify a specific test, click on the Modify
icon available near the test.
- Upon selection of a test, all the measures associated with the selected test,
but which are not yet associated with the given user, Category type, and Report type combination, will appear in the DISASSOCIATED MEASURES list.
- Now, from the DISASSOCIATED MEASURES list, select the
measures for which reports of the selected type are to be generated.
- Next, click on the ASSOCIATE
icon to transfer the
selected measures to the ASSOCIATED MEASURES list.
- Finally, click on the Update button. Now, whenever the
chosen user logs into the eG Reporter and attempts to generate Network
Reports of the selected Report type, the same will be
generated for each of the measures listed in the ASSOCIATED MEASURES list.
- Now, to disassociate the measures, select them from the ASSOCIATED
MEASURES list, click on the DISASSOCIATE
,
and finally, click on the Update button.
- To delete a test, click on the Delete
icon.
For configuring reports of the System
category, choose a user, select the System option, and proceed in the same
manner as discussed above.
For configuring reports belonging to
the Application category, select the Application option after selecting a user, and
proceed as follows:
- Select a Report type from the
list box.
- Next, for generating reports for
measures associated with a particular component type, select a Component
type.
- Then, from the Component list box that lists all the
managed components of the selected Component type, select the Component
for which reports are to be generated.
- Once this is done, all the measures that have already been associated (if
any) with the given combination of user, Category type, Report
type, Component type, and Component, will be displayed.
- Next, the test that are applicable for the selected component will be listed. To modify a specific test, click on the Modify
icon available near the test.
- Once a test is selected for modification, all the
measures associated with the selected test will appear in the DISASSOCIATED
MEASURES list.
- Now, from the DISASSOCIATED
MEASURES list, select the measures for which reports of the
selected type are to be generated.
- Next, click on the ASSOCIATE
icon to transfer the selected measures to the ASSOCIATED
MEASURES list.
- Finally, click on the Update button. Now, whenever the
chosen user logs into the eG Reporter and attempts to generate Application
Reports of the selected Report type, the same will be
generated for each of the measures listed in the ASSOCIATED MEASURES list.
- Now, to disassociate the measures,
select them from the ASSOCIATED MEASURES list, click on the DISASSOCIATE
icon, and finally, click on the Update button.
- To delete a test, click on the Delete
icon.
For configuring reports belonging to
the Site category, first select a user from the Choose the user list, select the Site option, and
then, proceed to do the following:
- Select a Report type from the
list box.
- Next, the test that are applicable for the selected component will be listed. To modify a specific test, click on the Modify
icon available near the test.
- Once a test is selected, all the
measures associated with the selected test will appear in the DISASSOCIATED
MEASURES list.
- Now, from the DISASSOCIATED
MEASURES list, select the measures for which reports of the
selected type are to be generated.
- Next, click on the ASSOCIATE
icon to transfer the selected measures to the ASSOCIATED
MEASURES list.
- Finally, click on the Update button. Now, whenever the
chosen user logs into the eG Reporter and attempts to generate Site
Reports of the selected Report Type, the same will be
generated for each of the measures listed in the ASSOCIATED MEASURES list.
- Now, to disassociate the measures,
select them from the ASSOCIATED MEASURES list, click on the DISASSOCIATE
icon, and finally, click on the Update button.
- To delete a test, click on the Delete
icon.
|